Hybrid-LV-48V

Short Description:

Hybrid-48V LXP3-5K  : * Support max 8kW solar input * Integrated off grid backup power function, seamless switch between on grid and off  grid. * Support micro-grid operation, compatible with generator,able to start generator remotely * With max 10 pcs paralleling function ( only available for MG model ) * Free APP and website to remote monitor, setting and firmware update


  • Net weight: 21kg
  • Gross weight: 27kg
  • Inverter size: 45.5*47.6*18.1 cm
  • Package size: 55.5*64*32 cm, 20pcs per pallet for seashipment, 16pcs per pallet for airshipment
  • Certificates: AS4777, N4105,VDE0126,G59,G83,EN50438,EN50549,CEI0-21,CEI0-16, NRS097,IEC62109,IEC62040, EN61000
  • Application scenarios

    Specification

    Working modes for hybrid inverter

    CUSTOMIZE WORKING MODES FOR MULTI APPLICATION

    • Self-consumption mode as default mode
    • Force time use for area where power cost is different according to time
    • Support pure off grid application and generator input/control
    Adanced UPS function

    ENHANCE UPS

    • Integrated UPS function, external ATS free
    • Seamless switching within 0.01s with stronger back-up function
    • Max 4kW discharge power from battery*
    • Max 5kW back-up power when with solar and battery
    Parallel Energy storge system

    ADVANCED PARALLELING FUNCTION DESIGN*

    • Up to 10 units in parallel of UPS mode
    • Support single phase paralleling and to compose three phase system
    • Flexible battery group connection
    user friendly hybrid inverter

    FRIENDLY USAGE

    • With super charger to wake up battery when Li-ion battery shutdown
    • Fan less design, noise free
    • IP65 design, 20kg for easy installation
    Advance monitor system for ESS

    FREE APP AND MONITOR SYSTEM

    • APP is available for both IOS and Android system
    • Support remote monitor, setting and update
    • Multi-level system monitoring and management
    • Big data analysis for both inverter and battery

    System Connection

    A newly designed solar and energy storage hybrid inverter, capable to install in on-grid solar, off-grid solar and back-up systems.LXP Hybrid enables a programable and schedulable smart solar energy storage system to help increase your solar energy self-consumption rate, protect your home appliances from grid shortage, and balance your energy usage strategy to save energy bill.

     

    system connection for hybrid system

    Self Consumption

    Under Self Use mode the energy generated by PV will be mainly used by local loads, and rest will be stored in the battery, excessive power will be feed back into the grid. This is the default mode which will increase the self consumption rate and reduce the energy bill significantly

     

    Self consumption

    Force Time Us

    This mode suits for situation where the price difference of energy is big. User can set the charging and discharging time and priority of energy use under Force Tim-e Use mode. The user can also choose whether to charge the battery using grid power if the regulations permitted.

     

    Force time use

    Zero Export

    If there is regulations to limit the export power of a on-grid PV system, you could choose this mode to limit the export rate of your system’s output to the grid.

     

    Off-grid Working Mode

    If enabled UPS function, once the grid is protected accidently, the UPS mode will be automatically and seamlessly activated to ensure your important loads keep working without any black out. Due to the specially designed function, it can support the system to workas a back-up power system or off-grid system. Off-grid work-ing mode can also work when there is only PV.

     

    Run Without Battery

    An interesting solution based on LXP Hybrid for new solar installations, without a battery but leave full interfaces ready for energy storage retrofitting, user could retrofit the on-grid solar system to solar battery system simply by adding an energy storage battery and plugging into the reserved interfaces. Now you’ve get a fresh new idea when install solar.

     

    Paralleling Extensions

    Paralleling LXP inverters in one phase to extend the single phase system capacity for either hybrid or AC coupled energy storage applications.
    Paralleling LXP inverters (single phase inverters) to build a three phase system for either hybrid or AC coupled energy storage applications.
    Smart paralleling algorithm enable multiple configurable working modes under on-grid, off-grid or micro-grid applications.

    Micro-grid Systems

     Capable with micro-grid applications with various AC power sources
    Multiple configuration available to various applications of micro-grid solution
    Support multiple type of loads, Such as air conditioner, refrigerator
    Flexible programmable working modes, support scheduling on system operationSystem extendable
    Support purely off-grid installation

     


  • Previous:
  • Next:

  • Solar Input LXP3K LXP3.6K LXP4K LXP4.6K/5K
    Max.DC Input Power 6600W 7000W 7000W 8000W
    Nominal DC Input Voltage 360V.d.c 360V.d.c 360V.d.c 360V.d.c
    DC Input Voltage Range 100-550V.d.c 100-550V.d.c 100-550V.d.c 100-550V.d.c
    MPPT Voltage Range 120-500V.d.c 120-500V.d.c 120-500V.d.c 120-500V.d.c
    Start-up Voltage 140V.d.c 140V.d.c 140V.d.c 140V.d.c
    MPPT Number 2 2 2 2
    Max.DC Input Current 12.5/12.5A 12.5/12.5A 12.5/12.5A 12.5/12.5A
    Battery Input/Output
    Compatible Battery Type Lithium-ion/Lead-Acid Lithium-ion/Lead-Acid Lithium-ion/Lead-Acid Lithium-ion/Lead-Acid
    Nominal Battery Voltage 48V.d.c 48V.d.c 48V.d.c 48V.d.c
    Battery Voltage Range 40-60V.d.c 40-60V.d.c 40-60V.d.c 40-60V.d.c
    Max.Charge/Discharge Current 66A/66A 66A/66A 80A/80A 80A/80A
    Max.Charge/Discharge Power 3600W/3600W 3600W/3600W 4000W/4000W 4000W/4000W
    Charging Curve 3 stages 3 stages 3 stages 3 stages
    Max.Charge Voltage 59V 59V 59V 59V
    Capacity Battery 2-20kWh 2-20kWh 2-20kWh 2-20kWh
    AC Input/Output
    Nominal AC Output Power 3000W 3600W 4000W 4600W/5000W
    Max.AC Output Power 3000VA 3600VA 4000VA 4600VA/5000VA
    Max.AC Output Current 15A 16A 20A 25A
    Nominal AC Voltage 230V.a.c 230V.a.c 230V.a.c 230V.a.c
    AC Voltage Range 180-270V.a.c 180-270V.a.c 180-270V.a.c 180-270V.a.c
    Norminal AC Frenquency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
    AC Frenquency Range 45-55Hz/55-65Hz 45-55Hz/55-65Hz 45-55Hz/55-65Hz 45-55Hz/55-65Hz
    Power Factor  >0.99@rated power0.8lagging-0.8 leading Adjustable
    THDI <3% <3% <3% <3%
    UPS Output-with Battery
    UPS Max.Output Power without Solar 3000W 3600W 4000W 4000W
    UPS Max.Output Power with Solar 3000W 3600W 4000W 5000W
    UPS Nominal Output Voltage 230V.a.c 230V.a.c 230V.a.c 230V.a.c
    UPS Nominal Output Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
    UPS Nominal Output Current 13A 15.6A 17.4A 17.4A
    Peak Power without Solar 4500W,30s 4500W,30s 4500W,30s 4500W,30s
    THDV <3%@R-load <3%@R-load <3%@R-load <3%@R-load
    Switching Time Typical 0.01s Typical 0.01s Typical 0.01s Typical 0.01s
    Efficiency
    Euroupe Efficiency 97.50% 97.50% 97.50% 97.50%
    Mzx.Efficiency 97.90% 97.90% 97.90% 97.90%
    Battery Charge/Discharge  Efficiency 94.50% 94.50% 94.50% 94.50%
    Protection
    Reverse Polarity Protection Yes Yes Yes Yes
    Over Current/Voltage Protection Yes Yes Yes Yes
    Anti-islanding Protection Yes Yes Yes Yes
    AC Short-circuit Protection Yes Yes Yes Yes
    Leakage Current Protection Yes Yes Yes Yes
    Ground Fault Monitoring Yes Yes Yes Yes
    Grid Monitoring Yes Yes Yes Yes
    Ingress Protect Degree IP65/NEMA4X IP65/NEMA4X IP65/NEMA4X IP65/NEMA4X
    DC Switch Integrated Integrated Integrated Integrated
    General Data
    Dimensions(W/H/D) 455/476(565)/181 455/476(565)/181 455/476(565)/181 455/476(565)/181
    Weight 20kg 20kg 20kg 20kg
    Topology Transformerless(solar),HF(Battery) Transformerless(solar),HF(Battery) Transformerless(solar),HF(Battery) Transformerless(solar),HF(Battery)
    Cooling Concept Natural Convection Natural Convection Natural Convection Natural Convection
    Relatively Humidity 0-100% 0-100% 0-100% 0-100%
    Operating Temperature Range -25-60℃ -25-60℃ -25-60℃ -25-60℃
    Altitude <2000m <2000m <2000m <2000m
    Noise Emission <25dB <25dB <25dB <25dB
    Standby Consumption <10W <10W <10W <10W
    Display&Communication Interfaces LCD,RS485,WI-FI,Ethernet LCD,RS485,WI-FI,Ethernet LCD,RS485,WI-FI,Ethernet LCD,RS485,WI-FI,Ethernet
    Certification&Approvals AS4777,VDE-AR-N4105,VDE0126,G83,G59,EN50438,EN50549,CEI0-21,CEI0-16,NRS097,IEC62109,IEC62040,EN61000-6-1,EN61000-6-2,EN61000-6-3