All-In-One

Hign Performance

Integrated backup power function

Free remote monitoring&upgrade

Outdoor and indoor installation

Optimized heat control

Safer operation

Easy to use

No fan design
System Connection
A newly designed solar and energy storage hybrid inverter, capable to install on-grid solar, off-grid solar, and back-up systems.LXP Hybrid enables a programable and schedulable smart solar energy storage system to help increase your solar energy self-consumption rate, protect your home appliances from grid shortage, and balance your energy usage strategy to save energy bills.
Self Consumption
Under Self Use mode the energy generated by PV will be mainly used by local loads, and the rest will be stored in the battery, excessive power will be feedback into the grid. This is the default mode which will increase the self-consumption rate and reduce the energy bill significantly
Force Time Us
This mode suits situation where the price difference of energy is big. Users can set the charging and discharging time and priority of energy use under Force Time Use mode. The user can also choose whether to charge the battery using grid power if the regulations permitted.
Zero Export
If there are regulations to limit the export power of an on-grid PV system, you could choose this mode to limit the export rate of your system’s output to the grid.
Off-grid Working Mode
If enabled UPS function, once the grid is protected accidentally, the UPS mode will be automatically and seamlessly activated to ensure your important loads keep working without any blackout. Due to the specially designed function, it can support the system to work as a back-up power system or off-grid system. The off-grid work-ing mode can also work when there is only PV.
Run Without Battery
An interesting solution based on LXP Hybrid for new solar installations, without a battery but leave full interfaces ready for energy storage retrofitting, a user could retrofit the on-grid solar system to a solar battery system simply by adding an energy storage battery and plugging it into the reserved interfaces. Now you’ve got a fresh new idea when installing solar.
Paralleling Extensions
Paralleling LXP inverters in one phase to extend the single-phase system capacity for either hybrid or AC coupled energy storage applications.
Paralleling LXP inverters (single-phase inverters) to build a three-phase system for either hybrid or AC coupled energy storage applications.
The smart paralleling algorithm enables multiple configurable working modes under on-grid, off-grid, or micro-grid applications.
Micro-grid Systems
Capable with micro-grid applications with various AC power sources
Multiple configurations available to various applications of micro-grid solution
Support multiple types of loads, Such as air conditioner, refrigerator
Flexible programmable working modes, support scheduling on system operation system extendable
Support purely off-grid installation
Solar Input | LXP3K | LXP3.6K | LXP4K | LXP4.6K/5K |
Max.DC Input Power | 6600W | 7000W | 7000W | 8000W |
Nominal DC Input Voltage | 360V.d.c | 360V.d.c | 360V.d.c | 360V.d.c |
DC Input Voltage Range | 100-550V.d.c | 100-550V.d.c | 100-550V.d.c | 100-550V.d.c |
MPPT Voltage Range | 120-500V.d.c | 120-500V.d.c | 120-500V.d.c | 120-500V.d.c |
Start-up Voltage | 140V.d.c | 140V.d.c | 140V.d.c | 140V.d.c |
MPPT Number | 2 | 2 | 2 | 2 |
Max.DC Input Current | 12.5/12.5A | 12.5/12.5A | 12.5/12.5A | 12.5/12.5A |
Battery Input/Output | ||||
Compatible Battery Type | Lithium-ion/Lead-Acid | Lithium-ion/Lead-Acid | Lithium-ion/Lead-Acid | Lithium-ion/Lead-Acid |
Nominal Battery Voltage | 48V.d.c | 48V.d.c | 48V.d.c | 48V.d.c |
Battery Voltage Range | 40-60V.d.c | 40-60V.d.c | 40-60V.d.c | 40-60V.d.c |
Max.Charge/Discharge Current | 66A/66A | 66A/66A | 80A/80A | 80A/80A |
Max.Charge/Discharge Power | 3600W/3600W | 3600W/3600W | 4000W/4000W | 4000W/4000W |
Charging Curve | 3 stages | 3 stages | 3 stages | 3 stages |
Max.Charge Voltage | 59V | 59V | 59V | 59V |
Capacity Battery | 2-20kWh | 2-20kWh | 2-20kWh | 2-20kWh |
AC Input/Output | ||||
Nominal AC Output Power | 3000W | 3600W | 4000W | 4600W/5000W |
Max.AC Output Power | 3000VA | 3600VA | 4000VA | 4600VA/5000VA |
Max.AC Output Current | 15A | 16A | 20A | 25A |
Nominal AC Voltage | 230V.a.c | 230V.a.c | 230V.a.c | 230V.a.c |
AC Voltage Range | 180-270V.a.c | 180-270V.a.c | 180-270V.a.c | 180-270V.a.c |
Norminal AC Frenquency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
AC Frenquency Range | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz |
Power Factor | >0.99@rated power0.8lagging-0.8 leading Adjustable | |||
THDI | <3% | <3% | <3% | <3% |
UPS Output-with Battery | ||||
UPS Max.Output Power without Solar | 3000W | 3600W | 4000W | 4000W |
UPS Max.Output Power with Solar | 3000W | 3600W | 4000W | 5000W |
UPS Nominal Output Voltage | 230V.a.c | 230V.a.c | 230V.a.c | 230V.a.c |
UPS Nominal Output Frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
UPS Nominal Output Current | 13A | 15.6A | 17.4A | 17.4A |
Peak Power without Solar | 4500W,30s | 4500W,30s | 4500W,30s | 4500W,30s |
THDV | <3%@R-load | <3%@R-load | <3%@R-load | <3%@R-load |
Switching Time | Typical 0.01s | Typical 0.01s | Typical 0.01s | Typical 0.01s |
Efficiency | ||||
Euroupe Efficiency | 97.50% | 97.50% | 97.50% | 97.50% |
Mzx.Efficiency | 97.90% | 97.90% | 97.90% | 97.90% |
Battery Charge/Discharge Efficiency | 94.50% | 94.50% | 94.50% | 94.50% |
Protection | ||||
Reverse Polarity Protection | Yes | Yes | Yes | Yes |
Over Current/Voltage Protection | Yes | Yes | Yes | Yes |
Anti-islanding Protection | Yes | Yes | Yes | Yes |
AC Short-circuit Protection | Yes | Yes | Yes | Yes |
Leakage Current Protection | Yes | Yes | Yes | Yes |
Ground Fault Monitoring | Yes | Yes | Yes | Yes |
Grid Monitoring | Yes | Yes | Yes | Yes |
Ingress Protect Degree | IP65/NEMA4X | IP65/NEMA4X | IP65/NEMA4X | IP65/NEMA4X |
DC Switch | Integrated | Integrated | Integrated | Integrated |
General Data | ||||
Dimensions(W/H/D) | 455/476(565)/181 | 455/476(565)/181 | 455/476(565)/181 | 455/476(565)/181 |
Weight | 20kg | 20kg | 20kg | 20kg |
Topology | Transformerless(solar),HF(Battery) | Transformerless(solar),HF(Battery) | Transformerless(solar),HF(Battery) | Transformerless(solar),HF(Battery) |
Cooling Concept | Natural Convection | Natural Convection | Natural Convection | Natural Convection |
Relatively Humidity | 0-100% | 0-100% | 0-100% | 0-100% |
Operating Temperature Range | -25-60℃ | -25-60℃ | -25-60℃ | -25-60℃ |
Altitude | <2000m | <2000m | <2000m | <2000m |
Noise Emission | <25dB | <25dB | <25dB | <25dB |
Standby Consumption | <10W | <10W | <10W | <10W |
Display&Communication Interfaces | LCD,RS485,WI-FI,Ethernet | LCD,RS485,WI-FI,Ethernet | LCD,RS485,WI-FI,Ethernet | LCD,RS485,WI-FI,Ethernet |
Certification&Approvals | AS4777,VDE-AR-N4105,VDE0126,G83,G59,EN50438,EN50549,CEI0-21,CEI0-16,NRS097,IEC62109,IEC62040,EN61000-6-1,EN61000-6-2,EN61000-6-3 |
Solar Input | LXP4K HB | LXP5K HB | LXP6K HB |
Max.DC Input Power | 7000W | 8000W | 8000W |
Nominal DC Input Voltage | 360V.d.c | 360V.d.c | 360V.d.c |
DC Input Voltage Range | 100-550V.d.c | 100-550V.d.c | 100-550V.d.c |
MPPT Voltage Range | 120-500V.d.c | 120-500V.d.c | 120-500V.d.c |
Start-up Voltage | 140V.d.c | 140V.d.c | 140V.d.c |
MPPT Number | 2 | 2 | 2 |
Max.DC Input Current | 12.5/12.5A | 12.5/12.5A | 12.5/12.5A |
Battery Input/Output | |||
Compatible Battery Type | Lithium-ion/Lead-Acid | Lithium-ion/Lead-Acid | Lithium-ion/Lead-Acid |
Nominal Battery Voltage | 250V.d.c | 250V.d.c | 250V.d.c |
Battery Voltage Range | 90-450V.d.c | 90-450V.d.c | 90-450V.d.c |
Max.Charge/Discharge Current | 20A/20A | 20A/20A | 20A/20A |
Max.Charge/Discharge Power | 4000W/4000W | 5000W5000W | 6000W/6000W |
Charging Curve | 3-stages | 3-stages | 3-stages |
AC Input/Output | |||
Nominal AC Output Power | 4000W | 5000W | 6000W |
Nominal AC Output Current | 17.5A | 21.7A | 26A |
Max.AC Output Current | 22A | 27A | 30A |
Nominal AC Voltage | 230V.a.c | 230V.a.c | 230V.a.c |
Optional AC Voltage Range | 180-270V.a.c | 180-270V.a.c | 180-270V.a.c |
Norminal AC Frenquency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
AC Frenquency Range | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz |
Power Factor | >0.99@rated power0.8lagging-0.8 leading Adjustable | ||
THDI | <3% | <3% | <3% |
UPS Output-with Battery | |||
UPS Nominal Power | 4000W | 5000W | 6000W |
UPS Nominal Voltage | 230V.a.c | 230V.a.c | 230V.a.c |
UPS Nominal Frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
UPS Nominal Current | 17.5A | 21.7A | 26A |
Peak Power | 5000W,30s | 6200W,30s | 6900W,30s |
THDV | <3%@R-load | <3%@R-load | <3%@R-load |
Switching Time | Typical 0.01s | Typical 0.01s | Typical 0.01s |
Efficiency | |||
Euroupe Efficiency | 96.50% | 96.50% | 96.50% |
Mzx.Efficiency | 97.50% | 97.50% | 97.50% |
Battery Charge/Discharge Efficiency | 97%/96.6% | 97%/96.6% | 97%/96.6% |
Protection | |||
Reverse Polarity Protection | Yes | Yes | Yes |
Over Current/Voltage Protection | Yes | Yes | Yes |
Anti-islanding Protection | Yes | Yes | Yes |
AC Short-circuit Protection | Yes | Yes | Yes |
Leakage Current Protection | Yes | Yes | Yes |
Ground Fault Monitoring | Yes | Yes | Yes |
Grid Monitoring | Yes | Yes | Yes |
Ingress Protect Degree | IP65/NEMA4X | IP65/NEMA4X | IP65/NEMA4X |
DC Switch | Integrated | Integrated | Integrated |
General Data | |||
Dimensions(W/H/D) | 455/476(565)/181 | 455/476(565)/181 | 455/476(565)/181 |
Weight | 20kg | 20kg | 20kg |
Topology | Transformerless | Transformerless | Transformerless |
Cooling Concept | Natural Convection | Natural Convection | Natural Convection |
Relatively Humidity | 0-100% | 0-100% | 0-100% |
Operating Temperature Range | -25-60℃ | -25-60℃ | -25-60℃ |
Altitude | <2000m | <2000m | <2000m |
Noise Emission | <25dB | <25dB | <25dB |
Standby Consumption | <10W | <10W | <10W |
Display&Communication Interfaces | LCD/LED/RS485/WI-FI/CAN | LCD/LED/RS485/WI-FI/CAN | LCD/LED/RS485/WI-FI/CAN |
Certification&Approvals | CEI0-21,IEC62109-1-2,IEC62040, EN61000-6-1,EN61000-6-2,EN61000-6-3 |